R1#
hostname R1
!
interface Serial0/0
ip address 10.1.1.1 255.255.255.248
encapsulation frame-relay
clock rate 2000000
frame-relay map ip 10.1.1.2 102 broadcast
frame-relay map ip 10.1.1.3 103 broadcast
frame-relay map ip 10.1.1.4 104
no frame-relay inverse-arp
!
R1#
R2#
R2#
interface Serial0/0
no ip address
encapsulation frame-relay
clock rate 2000000
no frame-relay inverse-arp
!
interface Serial0/0.221 point-to-point
ip address 10.1.1.2 255.255.255.248
snmp trap link-status
frame-relay interface-dlci 201
!
R2#
R3#
interface Serial0/0
no ip address
encapsulation frame-relay
clock rate 2000000
no frame-relay inverse-arp
!
interface Serial0/0.321 point-to-point
ip address 10.1.1.3 255.255.255.248
snmp trap link-status
frame-relay interface-dlci 301
!
R3#
R4#
R4#
interface Serial0/0
ip address 10.1.1.4 255.255.255.248
encapsulation frame-relay
clock rate 2000000
frame-relay map ip 10.1.1.1 401
R4#
R4#
//-----------------------------------//
R1#sh fram pvc
PVC Statistics for interface Serial0/0 (Frame Relay DTE)
Active Inactive Deleted Static
Local 3 0 0 0
Switched 0 0 0 0
Unused 0 0 0 0
DLCI = 102, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0/0
input pkts 771 output pkts 30 in bytes 258296
out bytes 3120 dropped pkts 0 in pkts dropped 0
out pkts dropped 0 out bytes dropped 0
in FECN pkts 0 in BECN pkts 0 out FECN pkts 0
out BECN pkts 0 in DE pkts 0 out DE pkts 0
out bcast pkts 0 out bcast bytes 0
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
pvc create time 12:15:25, last time pvc status changed 12:14:25
DLCI = 103, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0/0
input pkts 614 output pkts 0 in bytes 212444
out bytes 0 dropped pkts 0 in pkts dropped 0
out pkts dropped 0 out bytes dropped 0
in FECN pkts 0 in BECN pkts 0 out FECN pkts 0
out BECN pkts 0 in DE pkts 0 out DE pkts 0
out bcast pkts 0 out bcast bytes 0
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
pvc create time 12:15:26, last time pvc status changed 12:14:26
DLCI = 104, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0/0
input pkts 10 output pkts 10 in bytes 1040
out bytes 1040 dropped pkts 0 in pkts dropped 0
out pkts dropped 0 out bytes dropped 0
in FECN pkts 0 in BECN pkts 0 out FECN pkts 0
out BECN pkts 0 in DE pkts 0 out DE pkts 0
out bcast pkts 0 out bcast bytes 0
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
pvc create time 12:15:28, last time pvc status changed 12:14:28
R1#
R1#
R1#sh fram map
Serial0/0 (up): ip 10.1.1.2 dlci 102(0x66,0x1860), static,
broadcast,
CISCO, status defined, active
Serial0/0 (up): ip 10.1.1.3 dlci 103(0x67,0x1870), static,
broadcast,
CISCO, status defined, active
Serial0/0 (up): ip 10.1.1.4 dlci 104(0x68,0x1880), static,
CISCO, status defined, active
R1#
R2#sh fram pvc
PVC Statistics for interface Serial0/0 (Frame Relay DTE)
Active Inactive Deleted Static
Local 1 0 0 0
Switched 0 0 0 0
Unused 0 0 0 0
DLCI = 201, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0/0.221
input pkts 30 output pkts 775 in bytes 3120
out bytes 259680 dropped pkts 0 in pkts dropped 0
out pkts dropped 0 out bytes dropped 0
in FECN pkts 0 in BECN pkts 0 out FECN pkts 0
out BECN pkts 0 in DE pkts 0 out DE pkts 0
out bcast pkts 740 out bcast bytes 256040
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
pvc create time 12:18:44, last time pvc status changed 12:17:44
R2#
R3#sh fram pvc
PVC Statistics for interface Serial0/0 (Frame Relay DTE)
Active Inactive Deleted Static
Local 1 0 0 0
Switched 0 0 0 0
Unused 0 0 0 0
DLCI = 301, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0/0.321
input pkts 0 output pkts 620 in bytes 0
out bytes 214520 dropped pkts 0 in pkts dropped 0
out pkts dropped 0 out bytes dropped 0
in FECN pkts 0 in BECN pkts 0 out FECN pkts 0
out BECN pkts 0 in DE pkts 0 out DE pkts 0
out bcast pkts 620 out bcast bytes 214520
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
pvc create time 10:20:27, last time pvc status changed 10:19:26
R3#
R3#sh fram map
Serial0/0.321 (up): point-to-point dlci, dlci 301(0x12D,0x48D0), broadcast
status defined, active
R3#
R4#sh fram pvc
PVC Statistics for interface Serial0/0 (Frame Relay DTE)
Active Inactive Deleted Static
Local 1 0 0 0
Switched 0 0 0 0
Unused 0 0 0 0
DLCI = 401, DLCI USAGE = LOCAL, PVC STATUS = ACTIVE, INTERFACE = Serial0/0
input pkts 10 output pkts 10 in bytes 1040
out bytes 1040 dropped pkts 0 in pkts dropped 0
out pkts dropped 0 out bytes dropped 0
in FECN pkts 0 in BECN pkts 0 out FECN pkts 0
out BECN pkts 0 in DE pkts 0 out DE pkts 0
out bcast pkts 0 out bcast bytes 0
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
pvc create time 01:00:02, last time pvc status changed 00:58:59
R4#
沒有留言:
張貼留言